SafetyQuestion 105 of 110

Before servicing a sewage ejector pump, the plumber must control hazardous energy. What procedure prevents the pump from starting during service?

a.Lockout/tagout of the electrical disconnect, then verify zero energy
b.Post a verbal warning
c.Unplug only if convenient
d.Work quickly between cycles

Explanation

Lockout/tagout requires de-energizing the pump at its disconnect, applying a personal lock and tag, and verifying zero energy by attempting to start it before hands go near moving parts. An automatic float could start the pump unexpectedly and cause severe injury. Each worker applies their own lock.

Law Reference: 29 CFR 1910.147

Practice all 110 questions free — no signup required.

Related questions on this topic

Last reviewed: · editorial process

PrepPass Editorial Team · Verified against Master Plumber Licensing Exam (UPC/IPC-based) · How we review
Report