Design & SizingQuestion 22 of 110
A booster pump adds 52 psi. What is the equivalent head, in feet, that the pump develops? Use 1 psi = 2.31 ft of head.
a.52 ft
b.120 ft
c.78 ft
d.231 ft
Explanation
Head = psi x 2.31 = 52 x 2.31 = 120 ft. The 2.31 factor is the reciprocal of the 0.433 psi-per-foot relationship and converts pressure to the equivalent vertical column of water. Pump curves are usually plotted in feet of head, so this conversion is needed to read them.
Law Reference: UPC §610.0Practice all 110 questions free — no signup required.
Related questions on this topic
- A roof drains 4,800 ft^2 at a design rainfall rate of 4 in/hr. Using Q = 0.0104 x A x i, what is the storm design flow?
- A storm sizing table is published at 4 in/hr. A vertical leader lists a capacity of 4,600 ft^2 of roof at 4 in/hr. If the local design rate is only 2 in/hr, what roof area can that same leader serve?
- A booster pump must deliver 40 gpm and raise pressure by 45 psi. Using approximate water horsepower WHP = (gpm x psi) / 1,714, what is the water horsepower required (before pump efficiency)?
- A recirculation loop must deliver 6 gpm of hot water. Using v = 0.408 x Q / d^2, what inside diameter keeps the velocity at about 2 ft/s to limit erosion of the continuously circulated hot line?
- A water main runs 250 ft of developed length and the friction chart shows a loss of 6 psi per 100 ft at the design flow. How much pressure is lost to friction over the full run?
- A sewage ejector pump must handle a building with a discharge of 30 gpm against 18 ft of total head. Using WHP = (gpm x head in ft) / 3,960, what is the water horsepower?