Using the known-air-infiltration method, an appliance space of 10,000 ft^3 is credited with 0.35 air changes per hour of natural infiltration. How many cubic feet of infiltration air per hour does the space provide?
a.350 cfh
b.1,750 cfh
c.3,500 cfh
d.35,000 cfh
Explanation
Infiltration air = volume x air changes per hour = 10,000 x 0.35 = 3,500 cubic feet per hour. This method credits only the air that leaks through a standard building, which in a tight modern house is often too little for the appliance load. When it is insufficient, dedicated outdoor combustion air must be supplied.
Law Reference: IFGC §304.5Practice all 110 questions free — no signup required.
Related questions on this topic
- A hospital adds a nitrogen line for surgical tools alongside oxygen and medical air. What single feature most prevents a fatal mix-up of these medical/industrial gases at the outlet?
- A gas piping system must include a sediment trap (drip leg) ahead of certain appliances. What is the purpose and typical location of the drip leg?
- Each gas appliance must have an accessible manual shutoff. Where must the appliance shutoff valve be located?
- A gas appliance vent connector runs 12 ft horizontally to the chimney. Code requires a minimum upward rise of 1/4 in per foot toward the chimney. What total vertical rise must the connector have?
- A two-appliance system: appliance A needs 60 cfh and appliance B needs 40 cfh. Using the longest-length method, the section of pipe between the meter and the first tee carries what demand?
- A leak test on an in-service gas line uses a soap-bubble or electronic method rather than a pressure drop. When is the bubble/electronic leak check the appropriate method?
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against Master Plumber Licensing Exam (UPC/IPC-based) · How we review