A gas appliance vent connector runs 12 ft horizontally to the chimney. Code requires a minimum upward rise of 1/4 in per foot toward the chimney. What total vertical rise must the connector have?
a.1-1/2 in
b.6 in
c.12 in
d.3 in
Explanation
Rise = 1/4 in per ft x 12 ft = 3 in of upward slope from the appliance to the chimney. The rise keeps hot flue gas moving upward and prevents it from stalling and spilling back into the room. A level or downward-sloped connector defeats natural draft and can spill carbon monoxide.
Law Reference: IFGC §503.6Practice all 110 questions free — no signup required.
Related questions on this topic
- A gas piping system must include a sediment trap (drip leg) ahead of certain appliances. What is the purpose and typical location of the drip leg?
- Each gas appliance must have an accessible manual shutoff. Where must the appliance shutoff valve be located?
- Using the known-air-infiltration method, an appliance space of 10,000 ft^3 is credited with 0.35 air changes per hour of natural infiltration. How many cubic feet of infiltration air per hour does the space provide?
- A two-appliance system: appliance A needs 60 cfh and appliance B needs 40 cfh. Using the longest-length method, the section of pipe between the meter and the first tee carries what demand?
- A leak test on an in-service gas line uses a soap-bubble or electronic method rather than a pressure drop. When is the bubble/electronic leak check the appropriate method?
- An elevated industrial gas line operates at 5 psi and is regulated down for appliances rated in inches of water column. Using 1 psi = 27.7 in water column, what is 5 psi expressed in inches of water column?
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against Master Plumber Licensing Exam (UPC/IPC-based) · How we review