Core TradesQuestion 107 of 700

Counter flashing at a chimney is installed so that its top edge is embedded in or tucked into a mortar joint of the masonry, MAINLY to:

a.Cover the top of the base flashing and shed water over it so no water gets behind the flashing
b.Hold the chimney together
c.Provide a decorative trim only
d.Support the roof deck

Explanation

Counter flashing tucks into the masonry and laps over the base flashing so runoff sheds outward and cannot get behind the flashing where the base flashing turns up the chimney. It does not structurally hold the chimney, act as mere decoration, or support the deck.

Law Reference: 2025 CA Building Code, Chapter 15 (Roof Assemblies)