Finish TradesQuestion 234 of 700

Before installing resilient flooring over a concrete slab, moisture is tested. In the anhydrous calcium chloride test (MVER), results are reported in:

a.Percent slope of the slab
b.Degrees of surface temperature
c.Pounds per square inch of compressive strength
d.Pounds of moisture emitted per 1,000 square feet in 24 hours

Explanation

The calcium chloride test measures moisture vapor emission rate (MVER) in pounds per 1,000 square feet per 24 hours, which is compared to the flooring manufacturer's limit. Slope, temperature, and compressive strength are unrelated to that moisture measurement.

Practice all 700 questions free — no signup required.

Related questions on this topic

Last reviewed: · editorial process

PrepPass Editorial Team · Verified against California CSLB General Building (B) Trade Examination · How we review
Report