The in-situ relative humidity (RH) probe test (per ASTM F2170) is another way to check a concrete slab before flooring. Many resilient flooring manufacturers set an acceptable internal RH limit at about:
a.75 to 80 percent
b.10 to 15 percent
c.50 percent exactly, never higher
d.99 percent
Explanation
In-situ RH probes commonly must read at or below roughly 75 to 80 percent (per the specific product) for resilient flooring to be installed safely. Ten to 15 percent is unrealistically dry, a flat 50 percent cap is stricter than most products require, and 99 percent is far too wet.
Practice all 700 questions free — no signup required.
Related questions on this topic
- In a commercial kitchen or a setting exposed to acids and constant washdown, which grout offers the BEST stain and chemical resistance?
- After grouting a tile wall, a light cloudy film remains on the tile faces. This grout haze is BEST removed by:
- Before installing resilient flooring over a concrete slab, moisture is tested. In the anhydrous calcium chloride test (MVER), results are reported in:
- Before nailing down solid strip hardwood over a wood subfloor, an installer checks moisture content of BOTH the flooring and the subfloor. Best practice is to keep the difference between them within about:
- At the doorway between a tile floor and a lower carpeted room, which transition piece is generally the BEST choice to bridge the height difference?
- Stretch-in (tackless) carpet installation over cushion relies on gripper strips at the room perimeter. When placing those strips, the pins should point:
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against California CSLB General Building (B) Trade Examination · How we review