Planning & EstimatingQuestion 637 of 700
On construction drawings, what does a 'revision cloud' with a triangular 'delta' symbol indicate?
a.An area of the drawing that has been changed, with the delta noting the revision number.
b.The true-north orientation of the site.
c.A required fire-rated wall assembly.
d.The location of a survey benchmark elevation.
Explanation
Correct: a revision cloud outlines the changed area and the triangular delta next to it carries the revision number, alerting readers to what changed and when. The north orientation is shown by a north arrow. Fire-rated assemblies are called out by rating notes/symbols. A benchmark is a datum reference, marked differently.
Practice all 700 questions free — no signup required.
Related questions on this topic
- On a civil drawing using an engineer's scale of 1 inch = 20 feet, a property line measures 4.5 inches on the paper. What is its actual length, and how does an engineer's scale differ from an architect's scale?
- Which drawing type shows a building as if cut vertically to reveal interior heights, floor and wall assemblies, and how components connect?
- On a set of construction drawings, what is the PRIMARY purpose of a door schedule?
- Which statement BEST reflects required inspection timing for concealed work?
- During interior work, in what order must inspections generally occur before the walls are closed up?
- In critical path method (CPM) scheduling, which statement is correct?