Branch Circuits & WiringQuestion 116 of 521
In a dwelling living room, general-purpose receptacles must be placed so that no point measured horizontally along the floor line of any wall space is farther than what distance from a receptacle?
a.6 ft
b.8 ft
c.10 ft
d.12 ft
Explanation
Section 210.52(A) requires receptacles so no point along the wall line is more than 6 ft from an outlet, which effectively caps spacing at 12 ft. This lets any 6-ft appliance cord reach an outlet without an extension cord. 8, 10, and 12 ft each exceed the 6-ft reach the rule protects.
Law Reference: 2023 NEC §210.52(A)Practice all 521 questions free — no signup required.
Related questions on this topic
- For dwelling receptacle spacing under 210.52(A), any wall space that is how wide or wider is counted as usable wall space requiring a receptacle?
- Along a dwelling kitchen countertop, receptacles must be installed so that no point along the wall counter space is more than what distance, measured horizontally, from a receptacle?
- A kitchen wall counter space is required to be served by a countertop receptacle when the counter is at least what width?
- What is the minimum number of 20-ampere small-appliance branch circuits required to serve the receptacle outlets in a dwelling kitchen, pantry, breakfast room, and dining room?
- The dwelling laundry receptacle outlet(s) required by 210.52(F) must be supplied by a branch circuit of at least what rating, dedicated to the laundry?
- A dwelling bathroom receptacle outlet must be supplied by a branch circuit of at least what rating that serves only bathroom receptacle outlets?
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against California CSLB C-10 Electrical Trade Examination · How we review