Equipment & SystemsQuestion 339 of 521

General-purpose receptacles serving a dwelling-unit pool must be located at least how far from the inside walls of the pool?

a.3 feet
b.6 feet
c.10 feet
d.20 feet

Explanation

Section 680.22(A) requires general-purpose receptacles to be located at least 6 feet from the inside walls of the pool. A required receptacle for pump-motor service may be between 6 and 20 feet away with GFCI protection; placing general receptacles closer than 6 feet is not permitted.

Law Reference: 2023 NEC §680.22

Practice all 521 questions free — no signup required.

Related questions on this topic

Last reviewed: · editorial process

PrepPass Editorial Team · Verified against California CSLB C-10 Electrical Trade Examination · How we review