Water Supply & DistributionQuestion 60 of 360

A homeowner reports faucets that hammer and leak, and you measure 105 psi static. Besides installing arrestors at quick-closing valves, what is the primary corrective action?

a.Increase pressure to 120 psi
b.Remove all aerators
c.Do nothing under 110 psi
d.Install a pressure-reducing valve to bring static pressure to 80 psi or less

Explanation

Since 105 psi exceeds the 80 psi limit, the primary correction is a pressure-reducing valve to lower static pressure to 80 psi or less, which also reduces stress and hammer. Increasing pressure worsens the problem, removing aerators does not fix pressure, and doing nothing violates the 80 psi limit.

Law Reference: 2022 California Plumbing Code (CPC) §608.2