Water Supply & DistributionQuestion 59 of 120
A 60 ft straight run of CPVC hot water pipe will see a 70 degree F temperature change. Using a coefficient of thermal expansion of 0.000034 in per in per degree F, approximately how much will the run expand?
a.About 0.6 in
b.About 1.0 in
c.About 2.4 in
d.About 1.7 in
Explanation
Convert to inches first: 60 ft = 720 in, and 720 x 0.000034 x 70 = 1.71 in of movement, which is why an offset or expansion loop is needed. The 0.6 in and 1.0 in answers come from using only part of the temperature change or forgetting the foot-to-inch conversion. The 2.4 in answer uses a temperature change near 100 degrees F rather than the 70 degrees stated.
Practice all 120 questions free — no signup required.
Related questions on this topic
- A dwelling unit contains one flush tank water closet (2.5 WSFU), two lavatories (1.0 WSFU each), one bathtub with shower (4.0 WSFU), one kitchen sink (1.5 WSFU), one dishwasher (1.5 WSFU), and one clothes washer (4.0 WSFU). What is the total water supply fixture unit load?
- Using the standard fixture unit to gpm conversion curve, what happens to the estimated demand when the total water supply fixture unit load on a system is doubled?
- What is the minimum nominal size normally permitted for a water service pipe serving a building?
- The highest fixture in a building is 28 ft above the meter and requires 15 psi residual. Meter loss is 5 psi and calculated friction loss in the piping is 12 psi. What minimum static pressure is needed at the meter?
- Using velocity (fps) = 0.408 x flow (gpm) divided by the square of the inside diameter (in), what is the velocity of 12 gpm flowing in 3/4 in Type L copper with an inside diameter of 0.785 in?
- An existing galvanized steel water line is being extended with copper tube. What must be installed at the point where the two materials join?
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against Journeyman Plumber Licensing Exam (UPC/IPC-based) · How we review