Gas PipingQuestion 96 of 120

A gas range is connected with a listed appliance connector that runs 4 ft from the shutoff valve to the range. Which statement about this installation is correct?

a.It is not allowed; no connector may exceed 3 ft
b.It is allowed only if the connector passes through the cabinet wall behind the range
c.It is allowed only if a second connector is added to reach the valve
d.It is allowed, because ranges and clothes dryers may use connectors up to 6 ft long

Explanation

Most appliance connectors are limited to 3 ft, but ranges and clothes dryers are permitted connectors up to 6 ft, so a 4 ft connector is acceptable. Connectors may not pass through walls, floors, ceilings or partitions, and connectors may not be joined together or reused, which rules out the other choices.

Law Reference: IFGC §411.1

Practice all 120 questions free — no signup required.

Related questions on this topic

Last reviewed: · editorial process

PrepPass Editorial Team · Verified against Journeyman Plumber Licensing Exam (UPC/IPC-based) · How we review
Report