Framing & StructuralCâu 299 / 700
On a roof deck of wood structural panels installed without tongue-and-groove edges or solid blocking, what device is commonly used along unsupported panel edges to keep adjacent panels flush?
a.Hurricane ties
b.Framing clips
c.Draft stops
d.Panel edge (H) clips
Giải thích
Panel edge clips (H-clips) are set between rafters at unsupported panel edges to align adjacent panels and share load, allowing a thinner panel for a given span. Hurricane ties resist uplift at bearings, framing clips connect members, and draft stops subdivide concealed spaces; none align roof panel edges.
Trích dẫn luật: 2025 CA Residential Code §R803.2.3Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- On a wood structural panel span-rating stamp such as 24/16, what does the second number (16) represent?
- When wood structural panel subfloor or sheathing is installed, what approximate gap is customarily left at panel edges and ends for expansion?
- For maximum stiffness, how should the long dimension (face grain) of wood structural floor panels normally be oriented relative to the supports?
- When nailing wall sheathing, what is the BEST reason to follow the specified closer edge-nail spacing (for example 6 inches) rather than a wider spacing?
- For wood structural panel sheathing, how far should nails typically penetrate into the framing member to be effective?
- A glued-and-nailed subfloor squeaks after installation. Which construction detail MOST directly reduces the squeaks?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra