Core TradesCâu 42 / 700
Condensate from a high-efficiency (condensing) gas furnace is mildly acidic, so before or as it is discharged to an approved drain it should be:
a.Piped into the combustion-air intake
b.Discharged onto the roof surface
c.Returned to the gas supply line
d.Neutralized or routed to an approved corrosion-resistant drain
Giải thích
Condensing-furnace condensate is acidic and can corrode metal drains, so it is neutralized and/or sent to an approved corrosion-resistant drain. Routing it to the air intake, roof, or gas line is unsafe and improper.
Trích dẫn luật: 2025 CA Mechanical Code (CMC) §310 (Condensate)Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- Under the California Energy Code, a residential exhaust fan rated below about 90 CFM must generally meet a MINIMUM efficacy of about:
- The outlet of a bathroom or clothes-dryer environmental exhaust duct must terminate:
- In a dwelling, makeup air must generally be provided for a kitchen exhaust hood once its rated airflow exceeds about:
- A continuous membrane roof (such as built-up or single-ply) is generally required instead of shingles when the roof slope is LESS THAN about:
- Where an ice barrier is required, it must extend from the eave edge to a point at least how far inside the exterior wall line of the building?
- For asphalt shingles installed on slopes between 2:12 and 4:12, the underlayment must be applied as:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra