Framing & StructuralCâu 437 / 700
In a wood-framed dwelling, fireblocking must be installed in concealed stud wall cavities at the ceiling and floor levels and, along the horizontal run, at intervals not exceeding what distance?
a.4 feet
b.6 feet
c.10 feet
d.20 feet
Giải thích
Fireblocking cuts off concealed draft openings so fire cannot spread quickly through wall cavities; horizontally it is required at intervals not exceeding 10 feet, plus at ceiling and floor levels. 4 and 6 feet are stricter than required, and 20 feet far exceeds the code limit, leaving an unbroken chimney-like cavity.
Trích dẫn luật: 2025 CA Residential Code §R302.11Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- Behind exterior cement plaster (stucco) on a wood-framed wall, the code generally requires how many layers of an approved water-resistive barrier over the sheathing?
- Guards are required on a residential deck when the walking surface is located more than what height above the grade or surface below?
- Under conventional framing rules, deep solid-sawn floor joists (such as nominal 2x10 or 2x12) generally require blocking or bridging installed at intervals not exceeding what maximum spacing?
- When nailing wood structural panel subflooring or wall sheathing by hand, what is the typical fastener spacing required at the supported panel edges and at intermediate (field) supports?
- In conventional roof framing, collar ties (or ridge straps) used to resist wind uplift and keep the ridge from separating are generally installed in what part of the attic space?
- A common rafter must span a horizontal run of 8 feet and rise a vertical height of 6 feet from the top plate to the ridge. Ignoring overhang, what is the approximate line length of the rafter?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra