SafetyCâu 691 / 700

When atmospheric testing is performed before entering a permit-required confined space, in what ORDER should the atmosphere generally be tested?

a.Toxic gases first, then oxygen, then flammable
b.Flammable first, then toxic, then oxygen
c.Oxygen first, then flammable/combustible gases, then toxic contaminants
d.The order does not matter as long as all three are tested

Giải thích

Correct: test oxygen first (because many combustible-gas meters need adequate oxygen to read correctly), then flammable/combustible gases and vapors, and finally toxic contaminants. Starting with toxics or flammables can give false readings if oxygen is off. The order does matter for accurate, safe results, so 'order does not matter' is incorrect.

Trích dẫn luật: Cal/OSHA Title 8 CCR §5157

Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.

Câu hỏi liên quan cùng chủ đề

Cập nhật gần nhất: · quy trình kiểm tra

Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra