An older flexible connector is found kinked and corroded when a water heater is replaced. What is the correct action?
a.Reuse it since it still holds pressure
b.Straighten the kink and reinstall it
c.Replace it with a new listed connector rated for the appliance
d.Wrap it in tape and leave it
Giải thích
A kinked or corroded connector must be replaced with a new listed connector rated for the appliance and gas; connectors are not meant to be reused, straightened, or repaired. Kinks restrict flow and create weak points, and corrosion can lead to leaks. Installing a new connector at each appliance change is standard safe practice.
Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A sizing table (natural gas) shows 1/2-inch pipe carries 92 cfh and 3/4-inch pipe carries 190 cfh at the governing length. A section supplies a 40,000 BTU/hr wall furnace plus a 45,000 BTU/hr water heater. What is the smallest size that works?
- Which installation practice for a flexible appliance connector is correct?
- Why must horizontal and vertical gas piping be supported at the intervals required by code?
- Gas piping must pass through a concrete slab. What is the correct approach?
- When sizing gas piping, why does the code sometimes require adding equivalent lengths for fittings such as elbows and tees?
- A CSST system is being bonded. Which practice reflects correct bonding technique?