What is the maximum number of water closets permitted on a 3 inch horizontal fixture branch?
a.1
b.3
c.2
d.4
Giải thích
A 3 inch horizontal fixture branch is limited to a maximum of two water closets regardless of its 20 DFU capacity. This restriction exists because a 3 inch line cannot reliably carry the surge from more than two closets. Three or four water closets require a 4 inch branch.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §703.0 (Table 703.1)Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.