A monitor alarms for ventricular fibrillation, but the technician finds the patient sitting up, alert, and brushing her teeth, and a regular narrow-complex rhythm is visible between the chaotic sections. What is the most likely explanation?

a.Intermittent true ventricular fibrillation
b.Third-degree AV block
c.Pacemaker malfunction
d.Muscle movement artifact

Giải thích

An alert, talking patient cannot be in ventricular fibrillation, and the presence of underlying normal complexes marching through the chaos identifies the tracing as motion artifact. True ventricular fibrillation has no organized QRS complexes anywhere and produces immediate unresponsiveness. AV block and pacemaker failure both produce organized, measurable patterns rather than chaotic noise tied to the patient's activity.