A commercial kitchen has a two-compartment sink whose drain must not connect directly to the sanitary drainage system. How must it discharge?
a.Through an indirect waste with an air gap or air break into a receptor
b.Through a directly connected trap and trap arm
c.Through a backwater valve into the building sewer
d.Through a double trap arrangement
Giải thích
Fixtures that must be protected from sewage backflow discharge indirectly into an approved receptor through an air gap or air break so that no direct connection to the drainage system exists. A direct trap and trap arm connection defeats that protection, a backwater valve does not create the required physical separation, and double trapping of a fixture is prohibited outright.
Luyện miễn phí toàn bộ 120 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A kitchen sink is located in an island counter where no wall is available for a conventional vent. Which venting method is designed for this condition?
- An air admittance valve is used to vent an island sink. Which statement describes a correct installation?
- What is the maximum vertical distance permitted between a fixture outlet and the trap weir serving that fixture?
- A basement floor is below the elevation of the next upstream manhole on the public sewer. What device is required to protect the fixtures on that floor?
- A 3 in horizontal branch must gain 4-1/2 in of fall between two fixed points. At the minimum slope for 3 in pipe, what is the longest run that produces exactly that fall?
- A 4 in horizontal drain is sized to carry a load of drainage fixture units. Which pipe run carries the greatest DFU load for a given diameter?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với Journeyman Plumber Licensing Exam (UPC/IPC-based) · Quy trình kiểm tra