Fixtures & Water HeatersCâu 77 / 120
A laundry standpipe for a residential clothes washer is roughed in with the top of the standpipe 14 inches above the trap weir. Is the installation acceptable?
a.Yes, any height is acceptable as long as the trap is vented
b.Yes, 14 inches is within the allowable range
c.No, the standpipe must extend at least 18 inches and not more than 42 inches above the trap weir
d.No, the standpipe must be at least 24 inches and not more than 60 inches above the trap weir
Giải thích
A clothes washer standpipe must be a minimum of 18 inches and a maximum of 42 inches above the trap weir, so 14 inches is too short and the discharge is likely to back out of the pipe. Height is regulated regardless of venting, so the first choice is wrong. The 24 to 60 inch range in the last choice is not the code window.
Luyện miễn phí toàn bộ 120 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A shower compartment is framed 32 inches by 32 inches inside the finished walls. Does it meet the minimum area and minimum dimension requirements for a shower?
- An indirect waste pipe from a commercial ice machine is 1-1/2 inches in diameter and discharges into a floor sink. What is the minimum required air gap?
- A 3/8 inch indirect waste tube from a beverage dispenser discharges over an open receptor. Applying the air gap rule, what is the required air gap?
- A showerhead is rated at the maximum allowable flow. A user showers for 8 minutes. Assuming the head flows at its rated maximum, how much water is used?
- A public restroom is fitted with metering faucets. What is the maximum volume of water each faucet may deliver per metering cycle?
- A closet flange is set on a wood subfloor before the finished tile is installed, and the installer plans to seal the closet to the flange. Which practice is correct?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với Journeyman Plumber Licensing Exam (UPC/IPC-based) · Quy trình kiểm tra