Systems & CodeCâu 58 / 110
A water heater relief-valve discharge, softener drain, and condensate line all terminate at the same floor-level receptor. What must be true of the receptor and each connection?
a.All lines hard-connected
b.Each discharges by air gap into the receptor, which is trapped and vented
c.Lines share one trap
d.Lines terminate below the receptor rim
Giải thích
Each indirect line must discharge through an air gap into the receptor, and the receptor itself must be trapped and vented so it drains to the sanitary system without allowing sewer gas back. The air gaps keep the potable-related discharges from cross connecting. Hard connections or below-rim terminations would defeat the required physical break.
Trích dẫn luật: UPC §501.0Luyện miễn phí toàn bộ 110 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- An oil-water separator serves three garage floor drains each rated at 20 gpm. The code allows sizing at 75 percent of the total connected flow for diversity. What design flow sizes the separator?
- A laboratory discharges 10 gpm of acid waste that must be diluted with water at a 5-to-1 ratio (water to acid waste) before it enters the neutralizing tank. How much dilution water is required?
- An air admittance valve (AAV) is used to vent an island fixture. Which condition must be met for the AAV to be acceptable?
- A boiler feed with chemical treatment connects to potable water. This is a high-hazard connection. Which assembly protects the potable supply against backpressure from the pressurized boiler?
- A single-family residence has an underground lawn sprinkler system with no chemical injection and no downstream pressure. This is a low-hazard, backsiphonage-only condition. Which is the minimum acceptable backflow device?
- An air gap at a lavatory faucet must be maintained above the flood-level rim. If the effective opening of the faucet is 1/2 in and the outlet is near a single wall, the required gap is three times the opening. What is the minimum air gap?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với Master Plumber Licensing Exam (UPC/IPC-based) · Quy trình kiểm tra