Specimen HandlingCâu 77 / 100
A serum tube is centrifuged five minutes after collection and fibrin strands appear in the serum. What went wrong?
a.The tube was centrifuged at too low a speed
b.The serum was exposed to light
c.The tube contained too much clot activator
d.The specimen was spun before the clot had fully formed
Giải thích
A plain or gel serum tube needs roughly 30 minutes at room temperature to clot completely before centrifugation, and spinning early leaves fibrin that clogs analyzers and skews results. Speed affects separation quality but does not create fibrin. Clot activator quantity is fixed by the manufacturer, and light exposure affects photosensitive analytes rather than clot formation.
Trích dẫn luật: CLSI GP44Luyện miễn phí toàn bộ 100 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- Unless a test specifies otherwise, at what temperature are routine blood specimens transported?
- A tube is submitted with far less blood than the test requires. How is this documented as a rejection reason?
- A routine urinalysis cannot be tested for 90 minutes. What is the correct interim handling?
- Serum is transferred into a secondary aliquot tube for send-out testing. What must be done?
- A phlebotomist notices the expiration date on a box of lavender tubes passed last month. What is the concern?
- Why must additive tubes be mixed by gentle inversion rather than shaking?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với NHA Certified Phlebotomy Technician (CPT) Exam · Quy trình kiểm tra