DecontaminationCâu 2 / 100
A new employee asks why the department never uses saline to soak or moisten soiled surgical instruments. What is the correct explanation?
a.It neutralizes enzymatic detergent and stops protein breakdown
b.The chloride ions attack the passive layer and cause pitting and corrosion
c.It raises the pH of the soak bath above the safe range for stainless steel
d.It coagulates protein soil onto the instrument surface
Giải thích
Sodium chloride breaks down the chromium oxide passive layer that protects stainless steel, producing pitting, staining, and eventual instrument failure. Water with an appropriate presoak or enzymatic product is the correct choice. Protein coagulation is caused by heat, not saline, and pH shift is not the mechanism of chloride damage.
Trích dẫn luật: AAMI ST79Luyện miễn phí toàn bộ 100 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A surgical case has just ended and the scrub person is preparing instruments for transport to the decontamination area. What is the correct point-of-use treatment?
- What air pressure relationship should the decontamination area have compared with adjacent areas of the department?
- A facility engineer is rebalancing the ventilation system and asks what minimum air exchange rate the decontamination area requires. What should the technician answer?
- A facility engineer asks what temperature range the decontamination area should be maintained within. What is the correct answer?
- During a survey, an inspector reviews the department's daily environmental logs and asks what relative humidity range must be maintained in the work areas. What is correct?
- A technician is about to begin manual cleaning at an open sink where splashing is expected. Which personal protective equipment combination is required?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với HSPA Certified Registered Central Service Technician (CRCST) Exam · Quy trình kiểm tra