Core TradesQuestion 111 of 700
Continuous insulation (ci) is applied on the exterior side of the wall sheathing, over the studs, MAINLY to:
a.Replace the need for cavity insulation entirely
b.Reduce thermal bridging through the framing so the whole wall performs better
c.Serve as the water-resistive barrier
d.Add shear strength to the wall
Explanation
Continuous insulation covers the framing without interruption, reducing thermal bridging where studs would otherwise conduct heat, improving the whole-wall R-value. It supplements (not always replaces) cavity insulation, is not itself the water barrier, and does not provide shear strength.
Law Reference: 2025 CA Energy Code (Title 24, Part 6)Practice all 700 questions free — no signup required.
Related questions on this topic
- CALCULATION: Roofing is estimated in squares (1 square = 100 square feet). A gable roof has two rectangular planes, each 40 feet by 25 feet. How many squares of roofing are needed, before waste?
- In cold climates, an ice barrier (self-adhering membrane) is applied at the eaves of a shingle roof MAINLY to:
- Proper sequencing of roof components requires that water always flows over, not under, the layer below. Therefore drip edge at the eave and underlayment should be arranged so that:
- CALCULATION: A wall assembly has three layers with R-values of R-4 (sheathing), R-13 (cavity), and R-0.68 (interior finish). Ignoring air films, what is the total nominal R-value?
- An air barrier is installed in a building envelope MAINLY to:
- A water-resistive barrier (WRB) is being installed over wall sheathing. To shed water correctly, the horizontal laps must be arranged so that:
Last reviewed: · editorial process
PrepPass Editorial Team · Verified against California CSLB General Building (B) Trade Examination · How we review