OSHA 30 Construction — All Questions
The figures these questions turn on, laid out by section on dense colour pages you can print: OSHA 30-Hour Construction cheat sheet PDF — $9.99 →
420 questions
The employer's fall protection training must be documented with:
- a.No record kept at all
- b.A written certification with name, date, and trainer's signature✓
- c.A note of the worker's shoe size in the absence of a written program
- d.A verbal promise made once
Under 29 CFR 1926.503(b), the employer must prepare a written certification record with the employee's name, the training date(s), and the signature of the trainer or employer. The record verifies training occurred. It must be kept current.29 CFR 1926.503(b)
What is a 'leading edge' in fall protection terms?
- a.The edge of an office desk
- b.An edge of a floor or roof that changes location as work progresses✓
- c.The top of a portable ladder
- d.The front bumper of a work truck as a general rule of thumb on site provided the weather stays clear
Under 29 CFR 1926.500, a leading edge is the edge of a floor, roof, or formwork that changes location as additional sections are placed. Workers constructing a leading edge 6 feet or more up need fall protection. Leading-edge work is a recognized high-hazard activity.29 CFR 1926.500
A horizontal lifeline used for fall arrest must be:
- a.Designed and used under a qualified person with a safety factor of two✓
- b.Rigged by any worker on the spot
- c.Made from any spare rope available where the foreman signs off on it during the earlier phases of work
- d.Used with no engineering at all
Under 29 CFR 1926.502(d), horizontal lifelines must be designed, installed, and used under the supervision of a qualified person as part of a complete system maintaining a safety factor of at least two. Forces in a horizontal lifeline can far exceed the worker's weight. Engineering prevents anchor overload.29 CFR 1926.502(d)
A self-retracting lifeline that limits free fall to 2 feet or less must sustain a minimum tensile load of:
- a.3,000 pounds✓
- b.50 pounds
- c.200 pounds
- d.No minimum at all
Under 29 CFR 1926.502(d), self-retracting lifelines and lanyards that limit free fall to 2 feet or less must sustain a minimum tensile load of 3,000 pounds. Those that do not limit free fall to 2 feet must sustain 5,000 pounds. SRLs reduce free-fall distance and arrest forces.29 CFR 1926.502(d)
What does 'total fall distance' include when calculating clearance?
- a.Only the length of the lanyard for typical light-duty operations for most residential-scale jobs
- b.Free fall, deceleration distance, harness stretch, and a safety margin✓
- c.Only the time of day at work
- d.Only the worker's own height
For the clearance calculation under 29 CFR 1926.502(d), total fall distance combines the free fall, the deceleration (shock-absorber) distance, harness stretch, and a safety factor, measured from the anchor. If this exceeds the distance to the lower level, the worker hits the ground. This matters most when anchoring below the D-ring.29 CFR 1926.502(d)
A body belt may be used today for which purpose?
- a.Positioning or restraint, but not fall arrest✓
- b.Fall arrest as the primary system when working away from the edge
- c.No permitted purpose at all
- d.Lifting heavy loads by hand
Under 29 CFR 1926.502(d), body belts are prohibited for fall arrest because they can cause internal injuries and let a worker slip out. They may still be used in positioning device systems. A full-body harness is required for fall arrest.29 CFR 1926.502(d)
Guardrail systems used around holes for passing materials must:
- a.Be left fully open on all sides
- b.Rely on only a warning sign
- c.Never be installed at holes at all provided the weather stays clear under most routine jobsite conditions
- d.Have no more than two removable sides and be closed when not in use✓
Under 29 CFR 1926.502(b), when guardrails are used around holes used to pass materials, no more than two sides may have removable sections, and when not passing materials the hole must be guarded on all unprotected sides. This limits open edges. Workers are protected between transfers.29 CFR 1926.502(b)
Wire rope used as a guardrail top rail must be:
- a.Left plain and difficult to see during the earlier phases of work
- b.Coated heavily with waste oil
- c.Flagged at least every 6 feet with high-visibility material✓
- d.Removed entirely during the day
Under 29 CFR 1926.502(b), when wire rope is used for top rails it must be flagged at least every 6 feet with high-visibility material and resist 200 pounds. Flagging makes the rope visible. It must maintain the required height under load.29 CFR 1926.502(b)
How many workers may be attached to a single vertical lifeline at one time?
- a.As many as can physically fit as long as the tools look intact
- b.One worker per vertical lifeline✓
- c.Two workers to share the load
- d.Up to five workers at once
Under 29 CFR 1926.502(d), each worker must be attached to a separate vertical lifeline unless the system is specifically engineered for more. If one worker falls, a shared line could jeopardize others. Independent lines protect each worker.29 CFR 1926.502(d)
Guardrail systems must be surfaced to prevent which secondary hazard?
- a.Chemical liquid spills
- b.Loud grinding noises
- c.Fires started by friction for most residential-scale jobs
- d.Punctures, lacerations, and snagged clothing✓
Under 29 CFR 1926.502(b), guardrail systems must be built so they do not cause punctures or lacerations or snag clothing, and rail ends must not overhang terminal posts. Smooth surfaces prevent injuries when workers contact the rail. This detail improves usability.29 CFR 1926.502(b)
Want these explained in order? OSHA 30-Hour Construction — Complete Study Guide (2026) — PDF + EPUB, $14.99 · 14-day refund →
A Class A ground-fault circuit interrupter (GFCI) is designed to trip when it senses leakage current of approximately what level?
- a.Only when the circuit breaker also senses a dangerous overload downstream
- b.About 5 milliamperes (in the 4-6 mA range)✓
- c.At least 20 amperes flowing to the equipment
- d.Roughly 120 volts measured between the hot and neutral conductors
A Class A GFCI trips when leakage to ground reaches about 5 mA (the 4-6 mA range), well below the level that causes serious harm. Under 29 CFR 1926.404(b)(1), GFCI protection is a required means of protecting workers on temporary construction receptacles. It responds far faster and to far smaller currents than an ordinary circuit breaker.
Under an assured equipment grounding conductor program, how often must equipment grounding conductors be tested at a minimum?
- a.Only one time, when the equipment is first purchased from the manufacturer
- b.Once every calendar year regardless of how the equipment is handled on site
- c.Only after an employee reports receiving a noticeable electric shock
- d.At least every three months✓
Under 29 CFR 1926.404(b)(1)(iii), the assured equipment grounding conductor program requires testing before first use, after repairs, after any incident suspected of causing damage, and at intervals not exceeding three months. A designated competent person implements the program. Tested equipment is identified so workers know it was checked.
On a construction site, GFCI protection is generally required for which receptacles supplying temporary power?
- a.Only receptacles located inside a fully enclosed and heated office trailer
- b.Only receptacles rated above 480 volts serving fixed machinery
- c.120-volt, single-phase 15-, 20-, and 30-ampere receptacles not part of the permanent wiring✓
- d.Only the permanent building receptacles that the utility company has energized
29 CFR 1926.404(b)(1)(ii) requires GFCI protection for all 120-volt, single-phase 15-, 20-, and 30-ampere receptacles that are not part of the permanent wiring. This covers the temporary receptacles and portable tools common on job sites. The alternative is a full assured equipment grounding conductor program.
Which subpart of 29 CFR Part 1926 primarily covers electrical safety requirements for construction?
- a.Subpart CC, which addresses cranes and derricks used in construction
- b.Subpart P, which addresses excavations, trenching, and soil classification
- c.Subpart M, which is dedicated entirely to fall protection systems
- d.Subpart K✓
Subpart K (29 CFR 1926.400 through 1926.449) contains the electrical safety requirements for construction. It covers installation safety, safety-related work practices, safety-related maintenance, and safety requirements for special equipment. Subparts M, P, and CC address other hazards entirely.
For equipment operating near overhead power lines rated up to 50 kV, what is the minimum required clearance?
- a.10 feet✓
- b.About 42 inches, the same height used for a standard guardrail
- c.There is no set clearance as long as a spotter watches the load
- d.3 feet, the same clearance kept in front of an electrical panel
OSHA requires a minimum clearance of 10 feet for lines rated up to 50 kV, per 29 CFR 1926.1408 and 1926.600. For higher voltages the clearance increases by 4 inches for every additional 10 kV. All overhead lines should be treated as energized.
When equipment must work near overhead lines rated above 50 kV, how is the required clearance adjusted?
- a.It is reduced by half whenever a qualified signal person is present
- b.It increases 4 inches for every additional 10 kV above 50 kV✓
- c.It only matters when the humidity is high enough to cause arcing
- d.It stays fixed at 10 feet regardless of how high the line voltage climbs
Per 29 CFR 1926.1408, for lines over 50 kV the minimum clearance is 10 feet plus 4 inches for each 10 kV over 50 kV (or use the table/other options in the standard). Higher voltage can arc across greater distances. Utilities should be contacted to de-energize or insulate lines where feasible.
What is the primary function of lockout/tagout of electrical circuits under 29 CFR 1926.417?
- a.To label finished electrical assemblies before they are shipped to the customer
- b.To prevent circuits from being energized while workers install or repair them✓
- c.To keep an accurate written record of every employee's daily work hours
- d.To physically lock the tool crib and material storage areas overnight
29 CFR 1926.417 requires that controls and equipment be rendered inoperative and tagged, and circuits deenergized and locked or tagged, before work begins. This prevents inadvertent energizing while employees work on the circuit. It protects against electrocution and arc-flash injuries during installation and maintenance.
How does a tag differ from a lock in controlling hazardous electrical energy?
- a.A tag may be removed by anyone, while a lock must stay on the equipment forever
- b.A tag is a warning device only, while a lock physically prevents operation✓
- c.A tag physically blocks the switch, while a lock is only a written reminder
- d.There is no difference because both provide the same physical restraint of energy
A tag is a warning device that alerts workers not to operate a control, but it provides no physical restraint, as noted under 29 CFR 1926.417 and general lockout principles. A lock physically prevents the energy-isolating device from being moved. Where only tags are used, added means of protection are needed.
Under temporary wiring rules, lamps used for general illumination must be:
- a.Protected from breakage by a guard✓
- b.Rated for at least 480 volts even when used on a standard 120-volt circuit
- c.Wired directly to the utility service without any overcurrent protection installed
- d.Left completely uncovered so they provide the maximum possible light output
29 CFR 1926.405(a)(2)(ii)(E) requires that temporary lamps for general illumination be protected from accidental contact or breakage by a suitable guard. A broken bulb can expose live parts and create shock and ignition hazards. Metal-shell, paper-lined lampholders are prohibited.
Which practice with flexible extension cords is prohibited on construction sites?
- a.Choosing a cord marked for hard or extra-hard service in the field
- b.Keeping cords up off wet ground and away from sharp metal edges
- c.Fastening them with staples or running them through pinch points such as doorways✓
- d.Inspecting the cord jacket and plug for damage before each use of the tool
Under 29 CFR 1926.405(a)(2)(ii)(J) and 1926.416(e), flexible cords may not be run through doorways, windows, or holes that could pinch them, nor fastened with staples or hung in ways that damage the insulation. Damaged insulation creates shock and fire hazards. Cords may not be used as a substitute for fixed wiring.
What working clearance does OSHA generally require in front of energized electrical panels rated 600 volts or less?
- a.No clearance at all, so materials may be stacked against the panel to save room
- b.At least 3 feet of clear working space✓
- c.Exactly 10 feet, matching the clearance kept from overhead power lines
- d.Only enough room for the panel door to open a few inches
29 CFR 1926.403(i) requires sufficient access and working space around electric equipment, generally at least 3 feet of depth for equipment 600 volts or less. Blocking a panel delays emergency shutoff and increases arc-flash exposure. The space must be kept clear and not used for storage.
Portable electric tools that are double-insulated are permitted to be used without a grounding prong because:
- a.They automatically shut off before any fault current can ever reach the housing
- b.Their design provides two independent layers of insulation between live parts and the user✓
- c.Double insulation means the tool can safely be submerged in water while running
- d.The manufacturer removed the grounding prong to make the tool lighter to carry
Double-insulated tools, recognized under 29 CFR 1926.302 and 1926.404(f), use two independent insulation layers so a single failure will not energize the housing, allowing them to omit the grounding conductor. They are marked with a square-within-a-square symbol. They still must be kept dry and inspected before use.
How does a GFCI differ in purpose from an ordinary circuit breaker?
- a.A GFCI is only for direct current, while a breaker is only for alternating current
- b.A GFCI protects people from shock; a breaker protects wiring from overload✓
- c.They serve the identical purpose and can always be used interchangeably in a circuit
- d.A GFCI protects the wiring from overheating, while a breaker protects people from shock
A GFCI senses small ground-fault currents that can injure a person and trips in a fraction of a second, while a circuit breaker or fuse protects conductors from overcurrent and short circuits. The two devices address different hazards, so both are needed. GFCI use on construction sites is required by 29 CFR 1926.404(b)(1).
Around exposed energized parts, which employees are permitted to work on or near them?
- a.Any worker who has read the safety data sheet for the electrical equipment
- b.New apprentices on their first day, as long as a coworker watches them closely
- c.Any employee on the crew who happens to be wearing leather work gloves that day
- d.Only qualified persons trained to recognize and avoid the hazards✓
Under 29 CFR 1926.416 and the definitions in 1926.449, only qualified persons trained in the construction and operation of the equipment and in recognizing and avoiding electrical hazards may work on or near exposed energized parts. Unqualified persons must stay outside the approach boundaries. De-energizing is preferred whenever feasible.
In a battery-charging area for construction equipment, what specific atmospheric hazard must be controlled?
- a.The release of an inert gas that has no ignition potential whatsoever
- b.An excess of oxygen that makes ordinary tools too heavy to lift safely
- c.Accumulation of flammable hydrogen gas released during charging✓
- d.A buildup of harmless water vapor that only fogs up workers' safety glasses
Charging lead-acid batteries releases hydrogen, a highly flammable gas, so 29 CFR 1926.441 requires adequate ventilation and prohibits open flames and smoking in charging areas. Facilities for flushing eyes and neutralizing acid spills must also be provided. Hydrogen can explode if allowed to accumulate near an ignition source.
Before servicing equipment that contains capacitors, what precaution addresses stored electrical energy?
- a.Paint the capacitors a bright color so workers can see them more easily
- b.Work quickly so that any remaining charge does not have time to cause a shock
- c.Discharge the capacitors and verify zero energy before contact✓
- d.Assume the capacitors are safe because the main disconnect has been switched off
Capacitors can retain a dangerous charge after power is removed, so lockout/tagout procedures under 29 CFR 1926.417 require releasing or restraining stored energy and verifying a zero-energy state before work. Verification is done with a properly rated test instrument. Overlooking stored energy causes unexpected shocks.
Approximately what level of electric current passing through the body can cause a 'freezing' or inability to let go?
- a.Around 10 milliamperes✓
- b.Only currents above 240 volts, because voltage alone determines muscle control
- c.Any current at all, even a fraction of a microampere, causes muscle freezing
- d.Around 500 amperes, roughly the output of a large welding machine
At roughly 10 mA, muscular contraction can prevent a person from releasing an energized conductor, prolonging exposure. Currents near 100 mA through the chest can cause ventricular fibrillation. These physiological effects are why 29 CFR 1926.404(b)(1) mandates GFCI protection to limit shock current and duration.
Why should a metal or aluminum ladder never be used for electrical work near energized parts?
- a.Metal ladders are simply too heavy for most workers to carry to the work area
- b.Aluminum ladders rust quickly and therefore become structurally unsafe outdoors
- c.The reflective surface of a metal ladder can distract nearby crane operators
- d.Its conductive rails can carry current and electrocute the user✓
29 CFR 1926.1053(b)(12) prohibits using ladders with conductive side rails where the worker or ladder could contact energized parts. A nonconductive fiberglass ladder is used instead. A metal ladder can provide a direct path for fault current through the worker to ground.
When verifying that a circuit is de-energized before work, a qualified worker should:
- a.Touch the conductor briefly with a bare finger to feel whether it is warm
- b.Assume the circuit is dead if the overhead lights in the room are turned off
- c.Use a properly rated tester and confirm the tester works before and after✓
- d.Rely on the position of the wall switch alone without any instrument test
Safe verification requires a test instrument rated for the voltage, and the tester should be checked on a known live source before and after use (the 'test the tester' step). This confirms a true zero-energy state before contact, consistent with 29 CFR 1926.417 lockout/tagout verification. Never rely on switch position or indicator lights alone.
In a group lockout situation where several workers service the same equipment, how is worker protection ensured?
- a.The first worker to arrive locks it and the last worker to leave removes it for all
- b.Each authorized worker applies his or her own personal lock✓
- c.One supervisor applies a single lock that covers every worker on the entire crew
- d.Locks are unnecessary as long as a warning tag is hung on the main disconnect
In group lockout, each authorized employee places a personal lock on the energy-isolating device (often using a group lockbox), so the equipment cannot be re-energized until every worker removes his or her own lock. This follows the hazardous-energy control principles applied under 29 CFR 1926.417. It guarantees no one is still exposed when power is restored.
What is the primary danger of an arc blast, as distinct from the thermal burn of an arc flash?
- a.A pressure wave that can throw workers and rupture eardrums✓
- b.A buildup of harmless condensation on nearby electrical enclosure surfaces
- c.A slow release of odorless gas that gradually reduces the oxygen in the room
- d.A mild static discharge that only causes a tingling sensation in the fingertips
An arc blast produces a high-pressure wave and molten-metal shrapnel that can knock workers down, cause concussive injuries, and rupture eardrums, in addition to the intense heat of the arc flash. De-energizing before work is the best protection, and arc-rated PPE is used when energized work is unavoidable. These hazards are addressed under 29 CFR 1926.416 and consensus standard NFPA 70E.
According to OSHA's preferred approach, when may work be performed on energized electrical equipment?
- a.Only when de-energizing is infeasible or introduces greater hazards✓
- b.Any time the worker feels personally comfortable working on live circuits
- c.Only during daylight hours, regardless of whether the circuit can be shut off
- d.Whenever de-energizing the equipment would slow the project's schedule at all
The safest practice, reflected in 29 CFR 1926.416 and NFPA 70E, is to de-energize equipment before work; energized work is justified only when de-energizing is infeasible or would create a greater hazard. Even then, only qualified persons with proper PPE and an energized-work permit may proceed. Schedule convenience is not an acceptable justification.
Before digging or trenching, what step protects workers and equipment from buried electrical lines?
- a.Have underground utilities located and marked (call 811)✓
- b.Assume no lines exist unless the property owner specifically warns you
- c.Begin digging immediately and stop only if a spark is actually seen
- d.Dig a shallow test hole with a metal bar to feel for any hidden cables
Contacting the one-call service (811) to have utilities located and marked before excavation helps prevent striking energized underground lines, a serious electrocution and explosion hazard. This supports the excavation requirements of Subpart P and the electrical protections of Subpart K. Hand-digging is used to expose lines near the marks.
Splices and repairs in a flexible cord on a construction site must:
- a.Be wrapped in ordinary cloth tape and returned to service right away
- b.Be made only by the newest apprentice as part of on-the-job training
- c.Be left exposed so inspectors can easily see where the repair was made
- d.Retain the original insulation and strain-relief qualities✓
29 CFR 1926.405(g)(2)(iii) allows repair of hard-service cords only if the splice retains the insulation, outer sheath, and mechanical strength of the original, typically by molded or vulcanized methods. Ordinary tape does not qualify. Otherwise the cord must be replaced.
Why is even a 120-volt circuit potentially fatal to a worker?
- a.It cannot actually harm anyone because 120 volts is considered a low voltage
- b.It is dangerous solely because of the noise the circuit makes when it faults
- c.It can drive enough current through the body to stop the heart✓
- d.It only causes harm if the worker is also touching a much higher-voltage line
Fatalities occur at 120 volts because the current that flows depends on body resistance, which drops sharply when skin is wet, and as little as about 100 mA through the chest can cause fatal ventricular fibrillation. Low voltage is not the same as low hazard. This is why 29 CFR 1926.404(b)(1) requires GFCI protection on ordinary 120-volt receptacles.
If a mobile crane or aerial lift contacts an overhead power line, what should the operator generally do?
- a.Reach out and push the line away from the machine with a bare hand
- b.Climb out and walk normally back to the site office to report the contact
- c.Immediately step down to the ground while still holding the metal handrail
- d.Stay in the cab if possible and warn others to keep clear✓
If contact occurs and the equipment remains energized, the safest action is usually to stay in the cab, because stepping off can create a path for current through the body. If forced to exit due to fire, the operator should jump clear without touching the machine and ground at once, then shuffle away. These practices support 29 CFR 1926.1408 power-line safety.
What is the function of bonding metal parts of an electrical installation?
- a.To give the installation a uniform color for easier visual inspection
- b.To insulate each metal part completely from every other metal part nearby
- c.To connect them so there is no dangerous voltage difference between them✓
- d.To make the metal parts heavier so they resist vibration from equipment
Bonding connects metal parts so they are at the same electrical potential, preventing a dangerous voltage difference that could shock a worker who bridges two parts. It works together with grounding to provide a safe fault-current path. These grounding and bonding requirements appear in 29 CFR 1926.404(f).
Replacing a blown fuse with one of a higher amperage rating is dangerous because it:
- a.Changes the color of the indicator light on the electrical panel
- b.Voids the tool warranty but presents no real safety concern at all
- c.Makes the connected tools run noticeably slower than they should
- d.Defeats the overcurrent protection and can allow wiring to overheat✓
Overcurrent devices such as fuses and breakers are sized to protect the conductors; installing a higher-rated fuse allows excessive current that can overheat wiring and start a fire, contrary to 29 CFR 1926.404(e). Overcurrent protection must match the circuit design. Never bypass or upsize protective devices.
Disconnecting means and circuit breakers on a construction site must be:
- a.Located at least 25 feet from any receptacle used for portable tools
- b.Legibly marked to show their purpose unless obvious from location✓
- c.Painted the same color as the surrounding wall to avoid distraction
- d.Left completely unlabeled so that only electricians can identify them
29 CFR 1926.403(f) requires that each disconnecting means and overcurrent device be legibly marked to indicate its purpose unless located and arranged so the purpose is evident. Clear marking lets workers quickly shut off the correct circuit in an emergency. Unmarked panels delay a safe shutdown.
When a GFCI on a construction receptacle trips repeatedly ('nuisance tripping'), the correct response is to:
- a.Investigate and correct the fault rather than bypass the GFCI✓
- b.Remove or jumper out the GFCI so the tool can keep running without interruption
- c.Ignore it entirely because repeated tripping is a normal and harmless event
- d.Replace the GFCI with a higher-amperage fuse to stop the interruptions
Repeated tripping usually signals a real ground fault in the tool, cord, or wiring and must be investigated and corrected, never bypassed. Defeating GFCI protection removes a life-saving safeguard required by 29 CFR 1926.404(b)(1). The faulty equipment should be removed from service until repaired.
Enclosures and cabinets housing energized electrical parts are required primarily to:
- a.Reduce the electric bill by insulating the conductors from heat loss
- b.Guard against accidental contact with live parts✓
- c.Keep the energized parts warm enough to operate during cold weather
- d.Improve the appearance of the job site for visiting clients and inspectors
29 CFR 1926.403(i)(2) requires that live parts operating at 50 volts or more be guarded against accidental contact by enclosures or other approved means. This prevents inadvertent contact that could cause shock or arc flash. Dead-front covers and closed cabinet doors must be kept in place.
What does the term 'exposed' mean when applied to energized electrical parts?
- a.Parts that are fully enclosed inside a locked and grounded metal cabinet
- b.Parts that are only energized during scheduled nighttime maintenance work
- c.Parts that have been safely de-energized and verified with a rated tester
- d.Live parts a person could inadvertently touch or approach✓
In 29 CFR 1926.449, 'exposed' (as to live parts) means capable of being inadvertently touched or approached nearer than a safe distance and not suitably guarded, isolated, or insulated. Exposed energized parts create direct shock and arc-flash risk. They must be guarded or the circuit de-energized.
Flexible cords and cables used on construction sites must be rated for what kind of service?
- a.Any rating at all, because the cord jacket rating has no safety significance
- b.Ordinary residential light-duty use, which is the least expensive option available
- c.Indoor decorative use only, since job-site cords never touch the ground
- d.Hard or extra-hard usage✓
29 CFR 1926.405(g) requires flexible cords used on construction sites to be of a type listed for hard or extra-hard usage, marked on the jacket (for example S, SO, ST, STO). These jackets withstand abrasion, moisture, and rough handling. Light-duty household cords damage easily and create shock and fire hazards.
An 'exposed' overhead conductor should always be treated by construction workers as:
- a.Energized, until proven otherwise by the utility✓
- b.A convenient anchor point for tying off tools and small equipment
- c.Completely safe, because most overhead lines carry very little current
- d.Something that can be tested for voltage by tossing a wet rope over it
OSHA guidance and 29 CFR 1926.416(a) require workers to assume every overhead and exposed line is energized unless and until the owner confirms and it is visibly grounded. Contact with assumed-dead lines causes many electrocutions. Only the utility should verify and de-energize lines.
Why must a portable generator's frame typically be bonded and, where required, grounded?
- a.To make the generator quieter so it does not disturb nearby residents
- b.To increase the generator's fuel efficiency during long work shifts
- c.To allow the generator to be safely operated indoors without ventilation
- d.To provide a safe path for fault current and reduce shock risk✓
Bonding and grounding a generator, per 29 CFR 1926.404(f), provide a low-impedance path so that a fault energizing the frame will trip protection instead of shocking a worker. Many portable generators use a bonded neutral and can be treated as separately derived systems. Generators must never be run indoors due to carbon monoxide.
Which statement about carrying and unplugging cord-connected tools is correct?
- a.Wrapping the cord tightly around the tool casing improves the connection
- b.Always lift and swing the tool by its cord to keep your hands free
- c.Unplug tools only by pulling firmly and quickly on the cord itself
- d.Never carry a tool by its cord or yank the cord to unplug it✓
29 CFR 1926.416(e) prohibits using cords in ways that damage them, including carrying tools by the cord or pulling the cord to disconnect it. This stress can break the strain relief and expose live conductors. Grasp the plug, not the cord, when disconnecting.
A live-line barrier or insulating blanket near energized parts is used to:
- a.Keep rainwater off the conductors so they conduct electricity better
- b.Increase the voltage delivered to portable tools on the same circuit
- c.Prevent accidental contact by covering exposed live conductors✓
- d.Provide a comfortable surface for workers to rest tools during breaks
Insulating line hoses, blankets, and barriers cover exposed energized parts so a qualified worker is protected from inadvertent contact, consistent with safe work practices in 29 CFR 1926.416 and NFPA 70E. They are rated for the system voltage. Cover-up is part of energized-work protection when de-energizing is infeasible.
Which condition most increases the severity of an electric shock?
- a.Wet skin or standing in water, which lowers body resistance✓
- b.Using a tool that has an intact grounding prong and undamaged cord
- c.Wearing dry, well-insulated rubber-soled boots on a dry wooden platform
- d.Working in a warm, dry area away from any source of moisture at all
Moisture dramatically lowers the body's electrical resistance, allowing more current to flow for a given voltage and greatly worsening a shock. This is why GFCI protection under 29 CFR 1926.404(b)(1) and dry working conditions are emphasized. Keeping hands, tools, and connections dry is a basic control.
What is the correct interpretation of the 'limited approach boundary' around exposed energized parts?
- a.The point beyond which cell phones must be switched off on the site
- b.A line marking where the parking area for construction vehicles begins
- c.A distance unqualified persons must not cross without protection✓
- d.The maximum distance a crane load may swing during normal operation
The limited approach boundary, described in NFPA 70E and supported by 29 CFR 1926.417, is the distance from an exposed energized part that an unqualified person may not cross unless escorted by a qualified person and properly protected. Closer boundaries (restricted approach) apply to qualified persons. These boundaries limit shock exposure.
Dead-front covers and panel covers should be kept in place because they:
- a.Keep the circuit breakers warm so they trip more slowly under load
- b.Prevent accidental contact with energized busbars and terminals✓
- c.Help the electrical panel blend into the surrounding wall for appearance
- d.Are only decorative and may be removed whenever they are inconvenient
Dead-front covers guard energized busbars and terminals so workers cannot inadvertently contact them, meeting the guarding requirements of 29 CFR 1926.403(i). Removing covers exposes live parts and raises shock and arc-flash risk. Covers must be reinstalled after any work.