Finish TradesCâu 235 / 700
The in-situ relative humidity (RH) probe test (per ASTM F2170) is another way to check a concrete slab before flooring. Many resilient flooring manufacturers set an acceptable internal RH limit at about:
a.75 to 80 percent
b.10 to 15 percent
c.50 percent exactly, never higher
d.99 percent
Giải thích
In-situ RH probes commonly must read at or below roughly 75 to 80 percent (per the specific product) for resilient flooring to be installed safely. Ten to 15 percent is unrealistically dry, a flat 50 percent cap is stricter than most products require, and 99 percent is far too wet.
Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- In a commercial kitchen or a setting exposed to acids and constant washdown, which grout offers the BEST stain and chemical resistance?
- After grouting a tile wall, a light cloudy film remains on the tile faces. This grout haze is BEST removed by:
- Before installing resilient flooring over a concrete slab, moisture is tested. In the anhydrous calcium chloride test (MVER), results are reported in:
- Before nailing down solid strip hardwood over a wood subfloor, an installer checks moisture content of BOTH the flooring and the subfloor. Best practice is to keep the difference between them within about:
- At the doorway between a tile floor and a lower carpeted room, which transition piece is generally the BEST choice to bridge the height difference?
- Stretch-in (tackless) carpet installation over cushion relies on gripper strips at the room perimeter. When placing those strips, the pins should point:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra