When installing a skylight on a sloped roof, the head and side flashing should be integrated with the roofing so that:
a.Water sheds over the flashing and down the roof, with step/counter flashing lapped shingle-style
b.The flashing sits on top of the finished roofing at the head
c.Only sealant seals the skylight to the deck
d.The curb is set directly on the roofing felt with no flashing
Giải thích
Skylight flashing must be woven into the roofing shingle-style, with head flashing under the upper courses and step/side flashing lapped so water always runs over the flashing and down-slope. Flashing over the head roofing, sealant only, or a bare curb all invite leaks.
Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- Under the California Energy Code prescriptive requirements, residential windows must not exceed a maximum U-factor. A lower U-factor and a low SHGC together mean the window:
- A room's window area is being checked for natural light. A common code benchmark for required glazing (natural light) in a habitable room is a glazed area of at least ____ of the floor area of the room.
- A window unit has a glazed opening 4 feet wide by 5 feet tall in a room with 250 square feet of floor area. If the light requirement is 8 percent of floor area, does this single window meet it?
- Batt insulation is installed in a 2x6 wall cavity behind drywall. To achieve its rated R-value, the batt must be:
- A recessed ceiling light fixture is being covered by attic insulation as part of the finish. To avoid a fire hazard, the fixture must be:
- A new landscape irrigation system connects to the potable water supply. To protect drinking water from contamination, the system must include:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra