Framing & StructuralCâu 334 / 700
What minimum bearing length is commonly required at the ends of engineered wood floor members unless the manufacturer specifies otherwise?
a.1/2 inch
b.About 1-1/2 inches on wood or metal (and more on masonry), per the manufacturer
c.4 inches minimum always
d.No bearing is needed if hangers are used
Giải thích
Engineered floor members typically need on the order of 1-1/2 inches of end bearing on wood or metal (and more on masonry or concrete), following the manufacturer's tables, so the reaction is safely delivered. A 1/2 inch is too little, a flat 4-inch rule is not universal, and hangers still require adequate seat or nailing capacity.
Trích dẫn luật: 2025 CA Residential Code §R502.6Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- At the bearing ends of many wood I-joists, what component is often required to prevent web crushing or rotation?
- For laminated veneer lumber (LVL) and glued-laminated (glulam) beams, where must any holes or notches be located and sized?
- A glued-laminated (glulam) beam is stamped 'TOP' along one edge. Why must it be installed with that face up?
- At the ends of I-joists that rest on a wall, a continuous member closing the joist ends and transferring vertical/lateral load is called what?
- Where a concentrated load (such as a post from above) bears down over an I-joist at a support, what is often installed to carry that load past the joist without crushing it?
- CALCULATION: An engineered LVL header is specified as a 3-1/2 inch wide member built up from plies that are each 1-3/4 inch thick. How many plies are laminated together?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra