Planning & EstimatingCâu 545 / 700
You are coordinating a whole-house remodel that adds a bedroom and a gas furnace. Which combination BEST reflects the required alarm coordination?
a.Only a smoke alarm in the new bedroom; carbon monoxide alarms are optional
b.Smoke alarms in and near sleeping areas plus carbon monoxide alarms outside sleeping areas because fuel-fired equipment is present
c.A single carbon monoxide alarm in the garage only
d.Alarms are not required because the house is existing
Giải thích
Dwellings with fuel-burning appliances or attached garages require carbon monoxide alarms outside each separate sleeping area, and smoke alarms are required in each bedroom and adjacent to sleeping areas. A remodel adding a bedroom and gas furnace triggers both. Option a omits required CO alarms. Option c misplaces the only alarm. Option d wrongly assumes existing homes are exempt when work triggers upgrades.
Trích dẫn luật: 2025 California Residential Code §R315Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A basement bedroom plan shows an emergency escape and rescue opening with a clear opening HEIGHT of 22 inches and width of 30 inches. What is the BEST assessment?
- A deck guard detail shows vertical balusters spaced so a 5-inch sphere can pass between them. What is the BEST correction?
- A stair section detail calls out a graspable handrail mounted 42 inches above the stair nosings. What is the BEST response during plan review?
- A plan provides an attic access hatch of 20 in by 28 in for an attic that is over 30 square feet with more than 30 inches of headroom. What is the BEST correction?
- A 1,800-square-foot crawl space uses standard (non-vapor-barrier) under-floor ventilation openings. Using the common 1-to-150 ratio, what is the MINIMUM net ventilation area required?
- During construction you find the architectural drawings show a beam at one size but the structural drawings show a larger size for the same beam. What is the BEST first action?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra