CALCULATION: A branch circuit is protected by a 20-ampere breaker. Applying the common rule that a continuous load should not exceed 80 percent of the breaker rating, what is the maximum continuous load in amperes?
a.12 amperes
b.16 amperes
c.18 amperes
d.20 amperes
Giải thích
Maximum continuous load = 20 A x 0.80 = 16 amperes. The 80 percent rule keeps continuous loads from overheating the overcurrent device. 12 A uses 60 percent, 18 A uses 90 percent, and 20 A ignores the derating.
Trích dẫn luật: 2025 CA Electrical Code (based on NEC)Luyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- CALCULATION: A single-phase load draws 24 amperes at 240 volts. What is the apparent power in kilovolt-amperes (kVA)?
- A subpanel is fed from the main service panel in a detached structure. In a modern installation, the neutral (grounded) and equipment grounding (ground) conductors at the subpanel must be:
- A homeowner reports that a bedroom outlet works but the tester shows an open ground. The MOST likely cause is:
- When routing a nonmetallic-sheathed cable through holes bored in wood studs, the code generally requires that the hole be kept back from the stud edge, or a steel plate be installed, primarily to:
- A fixture drain is located far from any vent, and after installation the trap seals siphon out, letting sewer gas into the room. The MOST likely code violation is:
- An air admittance valve (AAV) is installed to vent an island sink where a conventional vent is impractical. The AAV must be installed:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra