Core TradesCâu 85 / 700
A fixture drain is located far from any vent, and after installation the trap seals siphon out, letting sewer gas into the room. The MOST likely code violation is:
a.The trap is too large
b.The trap arm exceeds the maximum developed length allowed to its vent
c.The pipe slope is too steep
d.The fixture is too close to the stack
Giải thích
When the trap arm (horizontal distance from trap to vent) exceeds the code maximum for its pipe size, the trap can self-siphon and lose its seal, admitting sewer gas. Trap size, moderate slope, and closeness to the stack are not what causes siphonage from an over-long trap arm.
Trích dẫn luật: 2025 CA Plumbing CodeLuyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A homeowner reports that a bedroom outlet works but the tester shows an open ground. The MOST likely cause is:
- CALCULATION: A branch circuit is protected by a 20-ampere breaker. Applying the common rule that a continuous load should not exceed 80 percent of the breaker rating, what is the maximum continuous load in amperes?
- When routing a nonmetallic-sheathed cable through holes bored in wood studs, the code generally requires that the hole be kept back from the stud edge, or a steel plate be installed, primarily to:
- An air admittance valve (AAV) is installed to vent an island sink where a conventional vent is impractical. The AAV must be installed:
- CALCULATION: A 3-inch horizontal drain pipe is installed at the common 1/4 inch per foot slope. Over a 40-foot run, how much does the invert drop from start to end?
- A wet vent serves a bathroom group. The key characteristic of a wet vent is that:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra