Core TradesCâu 87 / 700
CALCULATION: A 3-inch horizontal drain pipe is installed at the common 1/4 inch per foot slope. Over a 40-foot run, how much does the invert drop from start to end?
a.10 inches
b.5 inches
c.20 inches
d.40 inches
Giải thích
Drop = slope x length = 0.25 inch per foot x 40 feet = 10 inches. Answer 5 uses 1/8 inch per foot; 20 uses 1/2 inch per foot; 40 uses 1 inch per foot.
Trích dẫn luật: 2025 CA Plumbing CodeLuyện miễn phí toàn bộ 700 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- When routing a nonmetallic-sheathed cable through holes bored in wood studs, the code generally requires that the hole be kept back from the stud edge, or a steel plate be installed, primarily to:
- A fixture drain is located far from any vent, and after installation the trap seals siphon out, letting sewer gas into the room. The MOST likely code violation is:
- An air admittance valve (AAV) is installed to vent an island sink where a conventional vent is impractical. The AAV must be installed:
- A wet vent serves a bathroom group. The key characteristic of a wet vent is that:
- A garden hose is left submerged in a utility sink filled with soapy water while the faucet is on. This creates a cross-connection hazard because:
- Horizontal copper water piping must be supported at intervals so it does not sag and strain joints. Compared with copper, plastic (PEX or CPVC) piping generally requires:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB General Building (B) Trade Examination · Quy trình kiểm tra