Under the 2023 NEC, how may a receptacle be installed to serve a kitchen countertop or work surface?

a.Face-up in the countertop surface, as long as it is within 6 inches of the edge
b.Up to 12 inches below the countertop, if the overhang is 6 inches or less
c.On or above the countertop, not more than 20 inches above it (face-up only if listed for countertop use)
d.In the wall cabinet above the counter, within 30 inches of the surface

Giải thích

2023 NEC 210.52(C)(3) requires kitchen countertop receptacles to be on or above the counter, not more than 20 in (500 mm) above it; a face-up receptacle in the surface is allowed only if listed for countertop/work-surface use. Below-counter mounting (formerly permitted up to 12 in below) was removed in the 2020 NEC, and there is no allowance for face-up within 6 in of the edge or placement in the upper cabinet.

Trích dẫn luật: 2023 NEC §210.52(C)(3)

Luyện miễn phí toàn bộ 521 câu hỏi — không cần đăng ký.

Câu hỏi liên quan cùng chủ đề

Cập nhật gần nhất: · quy trình kiểm tra

Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-10 Electrical Trade Examination · Quy trình kiểm tra
Báo lỗi