Mạch nhánh & Đi dâyCâu 163 / 521
In an attached dwelling garage with two vehicle bays, at least how many receptacle outlets are required, and in what location?
a.One total, any wall
b.One near the door only
c.None
d.At least one in each vehicle bay
Giải thích
Section 210.52(G)(1) requires at least one receptacle outlet installed in each vehicle bay of a dwelling garage, not more than 5.5 ft above the floor. A two-bay garage therefore needs at least two. 'One total,' 'one near the door,' and 'none' do not satisfy the per-bay requirement.
Trích dẫn luật: 2023 NEC §210.52(G)(1)Luyện miễn phí toàn bộ 521 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- When counting conductors for box fill in a device box, each 14 AWG current-carrying conductor that originates outside the box and terminates or is spliced within it counts as how many conductors?
- A 125-volt receptacle located within 6 ft of the outside edge of a bathtub or shower stall in a dwelling requires what protection?
- Under 210.8(F), outdoor outlets for dwellings supplying equipment such as air-conditioning condensers, rated 150 volts or less to ground and 60 amperes or less, generally require what?
- A dwelling attached garage requires at least one branch circuit of what rating to supply the required garage receptacle outlets?
- A 125-volt, 15- or 20-ampere receptacle outlet for servicing must be installed within what distance of heating, air-conditioning, and refrigeration equipment?
- Bends in electrical metallic tubing (EMT) must be made so that which of the following is true?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-10 Electrical Trade Examination · Quy trình kiểm tra