A furnace installed in an upflow configuration discharges heated air in which direction?
a.Downward through the bottom
b.Upward through the top of the cabinet
c.Horizontally to the side
d.Directly outdoors
Giải thích
An upflow furnace pulls return air in at the bottom and discharges heated supply air out the top, typical for basement or closet installations with overhead ductwork. Downflow and horizontal furnaces are oriented for other duct arrangements. The airflow direction must match the duct layout.
Luyện miễn phí toàn bộ 110 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- Flexible duct connectors at the air handler are commonly used to accomplish what?
- Why should supply and return ducts be sealed with mastic or listed tape at joints?
- When installing a split-system condenser, adequate clearance around the unit is needed mainly to ensure what?
- A furnace located in an attic generally requires what for code-compliant service?
- The condensate drain line from a cooling coil is often fitted with a trap to accomplish what?
- What is the recommended practice for supporting horizontal refrigerant and drain lines?