RefrigerationCâu 59 / 110
Subcooling is measured at which point in the system?
a.At the evaporator outlet
b.At the condenser outlet (liquid line)
c.At the compressor suction
d.At the filter on the return duct
Giải thích
Subcooling is measured at the condenser outlet by comparing the liquid line temperature to the saturation temperature for the high-side pressure. It indicates how much the liquid has cooled below its condensing point. Subcooling is a primary charging check on TXV systems.
Luyện miễn phí toàn bộ 110 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A thermostatic expansion valve (TXV) controls refrigerant flow into the evaporator to maintain what?
- Superheat is defined as the temperature of the refrigerant vapor above what?
- A technician measures a suction pressure whose saturation temperature is 40 F and a suction line temperature of 52 F. What is the superheat?
- On a system with a condensing saturation temperature of 105 F and a liquid line temperature of 95 F, what is the subcooling?
- On a fixed-orifice (piston) system, which method is generally used to check the charge?
- Under EPA Section 608, what must a technician do with refrigerant before opening most systems for service?