Thoát nước, Nước thải & Thông hơiCâu 101 / 360
What is the minimum vent size for a 3 inch drain, using the half-diameter rule?
a.1-1/2 inch
b.2 inch
c.1-1/4 inch
d.3 inch
Giải thích
Half of a 3 inch drain is 1-1/2 inch, which is also above the 1-1/4 inch absolute minimum, so 1-1/2 inch is the minimum vent size. A 1-1/4 inch vent is below half the drain diameter here. A 2 or 3 inch vent is larger than the minimum this rule requires.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §904.0Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- The drainage fixture unit (DFU) value of a private bathtub is:
- The DFU value assigned to a single lavatory is:
- The DFU value of a residential kitchen sink is:
- Using the half-diameter rule, the minimum vent size for a 4 inch drain is:
- The required size of a vent pipe:
- In areas subject to frost closure, a vent extension through the roof must be increased to a minimum of 3 inches, and the change in size must be made at least:
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra