Thoát nước, Nước thải & Thông hơiCâu 130 / 360
A circuit vent serving a battery of floor-mounted fixtures on a horizontal branch may serve a maximum of how many fixtures?
a.6
b.8
c.10
d.12
Giải thích
A circuit vent may serve a battery of up to 8 fixtures connected to a horizontal branch drain. A single vent rises between the last two fixtures to serve the whole battery, and a relief vent may be required where fixtures discharge above. This method suits banks of floor-mounted water closets or urinals.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §911.0Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.