Thoát nước, Nước thải & Thông hơiCâu 137 / 360
Fixtures with flood-level rims located below the elevation of the next upstream manhole cover must be protected from sewer backflow by…
a.An approved backwater valve
b.A deeper trap seal
c.An air-admittance valve
d.A larger vent
Giải thích
Fixtures whose flood-level rims are below the next upstream manhole cover can flood when the public sewer surcharges, so they must discharge through an approved backwater valve. Fixtures above that elevation must not drain through the backwater valve, so they still drain by gravity if the valve closes. This protects low fixtures without impeding normal flow from higher ones.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §710.1Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- In a cold climate subject to frost closure, a vent through the roof must be enlarged to a minimum of 3 inches. Where must that increase in size be made?
- A sewage ejector receiving the discharge of a water closet must have a discharge pipe of not less than what diameter and be able to pass a 2-inch solid?
- A sump or receiving tank that collects sewage from fixtures located below the sewer level must be…
- An installed backwater valve must be…
- Under the CPC, rainwater (storm) drainage and sanitary sewage generally must…
- The air gap for an indirect waste pipe discharging into a receptor must be at least…