Thoát nước, Nước thải & Thông hơiCâu 135 / 360
A sewage ejector receiving the discharge of a water closet must have a discharge pipe of not less than what diameter and be able to pass a 2-inch solid?
a.1-1/4 inches
b.1-1/2 inches
c.2 inches (51 mm)
d.4 inches
Giải thích
A pump or ejector handling water-closet discharge must have a discharge pipe of at least 2 inches and be capable of passing a 2-inch spherical solid. This prevents clogging by the solids typical of sanitary sewage. Smaller effluent-only pumps are permitted only where they handle liquid waste without solids.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §710.0Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- What is the minimum diameter permitted for a vent pipe, regardless of the fixture it serves?
- A tall drainage stack with five or more branch intervals generally requires what to protect trap seals from pressure changes?
- In a cold climate subject to frost closure, a vent through the roof must be enlarged to a minimum of 3 inches. Where must that increase in size be made?
- A sump or receiving tank that collects sewage from fixtures located below the sewer level must be…
- Fixtures with flood-level rims located below the elevation of the next upstream manhole cover must be protected from sewer backflow by…
- An installed backwater valve must be…