Thoát nước, Nước thải & Thông hơiCâu 150 / 360
An air admittance valve for an individual or branch fixture vent must be a listed device complying with which standard?
a.ASSE 1017
b.ASSE 1051
c.ASSE 1070
d.ASME A112.6
Giải thích
Individual and branch-type air admittance valves must be listed to ASSE 1051. Stack-type AAVs are covered by a different listing (ASSE 1050). Using a valve listed to the correct standard ensures it seals against sewer gas and admits air reliably.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §918.0Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A vent must rise vertically to at least what point before it may offset horizontally, to keep waste water out of the dry vent?
- For a 2-inch trap arm, the maximum developed length from the trap weir to the vent (per the CPC trap-to-vent table) is approximately…
- Besides not being directly beneath a door, openable window, or air intake, a side-wall (through-wall) vent termination must also maintain required clearance from…
- Where a vent penetrates the roof, the plumber must provide…
- A sewage sump that receives water-closet discharge and is served by a pump must be provided with a vent that…
- For a building where sewage must be pumped and continuity of service is essential (such as public use), the CPC generally requires…