Thiết bị & Bình nước nóngCâu 175 / 360
Which of the following is prohibited on a water heater relief valve discharge line?
a.Running it to the outside of the building
b.Installing a trap in the line
c.Using CPVC rated for hot water
d.Sizing it full to the valve outlet
Giải thích
A trap must never be installed in a relief discharge line because standing water could freeze or block the emergency path. The line must drain freely by gravity with no valves or traps. It may terminate outside or to an approved receptor with an air gap.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §608.5Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.