Thiết bị & Bình nước nóngCâu 184 / 360
A house has a water meter with a check valve installed on the service. What must be added at the water heater to control thermal expansion?
a.A second T&P valve
b.A larger cold water pipe
c.An expansion tank or approved expansion control device
d.A pressure-reducing valve on the hot side
Giải thích
When a check valve, backflow preventer, or pressure-reducing valve creates a closed system, heated water cannot expand back into the main and pressure spikes. An expansion tank or listed expansion control device must be installed to absorb that thermal expansion. Without it, the relief valve may weep or the tank may be stressed.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §608.3Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A water heater drain pan must have a minimum depth of:
- The drain line from a water heater pan must be at least what pipe size?
- Where should a water heater pan drain terminate?
- Thermal expansion in a domestic hot water system is primarily caused by:
- A gas water heater is installed in a residential garage. To reduce the risk of igniting flammable vapors, the ignition source should generally be elevated above the floor by at least:
- A fuel-gas water heater installed in a small closet requires combustion air primarily to:
Cập nhật gần nhất: · quy trình kiểm tra