A single gas main serves a 40,000 BTU/hr water heater, a 100,000 BTU/hr furnace, and a 65,000 BTU/hr range. What total connected load must the main be sized to carry?
a.100,000 BTU/hr
b.165,000 BTU/hr
c.205,000 BTU/hr
d.40,000 BTU/hr
Giải thích
The section feeding all three appliances must carry the sum of their inputs: 40,000 plus 100,000 plus 65,000 equals 205,000 BTU/hr. Convert to cfh (about 205 cfh for natural gas) and size that section for the full connected load. Individual branches downstream only carry the demand beyond that point.
Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.