Which statement about listed flexible appliance connectors is correct?
a.They may be spliced together to gain length
b.They must not pass through a wall, floor, ceiling, or partition and must be accessible
c.They may be concealed permanently inside a finished wall
d.They are the same thing as CSST distribution tubing
Giải thích
A listed appliance connector is a single, one-piece final connection that must remain accessible and must not be run through walls, floors, ceilings, or partitions. Connectors may not be joined end-to-end or spliced to reach farther. CSST is a distribution piping product with its own rules and is not the same as a short appliance connector.
Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- A tankless natural gas water heater lists an input of 199,000 BTU/hr. Using 1,000 BTU per cubic foot, what gas demand must the branch supplying it be sized for?
- A building is served by an elevated-pressure (2 psi) gas system. What component is required near each appliance?
- What is the typical operating (manifold) pressure for a standard residential propane (LP) appliance?
- A sizing table (0.5 psi drop, natural gas) shows that 3/4-inch schedule 40 pipe at a 40-foot run carries 170 cfh, and 1-inch pipe carries 320 cfh. A section must supply a 250,000 BTU/hr load over that 40-foot run. What is the smallest listed size that works?
- Where should the sediment trap be installed in relation to the appliance shutoff valve and the appliance gas control?
- What is a common standard delivery pressure of natural gas to a typical single-family residence downstream of the utility meter?