An toànCâu 334 / 360

The atmosphere in a sewer vault tests as oxygen-deficient. Before any worker enters, what is the required corrective action?

a.Mechanically ventilate the space and retest until the atmosphere is within acceptable limits
b.Have the worker hold their breath and work quickly
c.Light a candle to burn off the bad air
d.Enter anyway since low oxygen is not dangerous for short tasks

Giải thích

Under Title 8 §5157, a hazardous atmosphere must be controlled by continuous mechanical (forced-air) ventilation, and the space must be retested to confirm it is within acceptable limits before and during entry. Ventilation dilutes and removes toxic or flammable gases and restores oxygen. Entering an oxygen-deficient space without ventilating is a frequent cause of confined-space fatalities.

Trích dẫn luật: Cal/OSHA Title 8 §5157

Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.

Câu hỏi liên quan cùng chủ đề

Cập nhật gần nhất: · quy trình kiểm tra

Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra
Báo lỗi