An toànCâu 347 / 360

A plumber is brazing a joint on a fitting that may be cadmium-plated in a small, poorly ventilated mechanical room. What is the primary hazard and control?

a.The fumes smell bad, so just open a window a crack
b.Toxic metal fumes (such as cadmium) require local exhaust ventilation and possibly respiratory protection
c.There is no fume hazard from brazing
d.Only the heat is a concern, not the fumes

Giải thích

Heating cadmium-plated or certain silver-alloy filler metals releases toxic metal fumes that can cause severe lung injury even at low visible levels. Cal/OSHA requires controlling such exposures with adequate ventilation, preferably local exhaust, and respiratory protection under §5144 when ventilation is insufficient. Working in a tight, unventilated space multiplies the hazard, so ventilation is the first line of defense.

Trích dẫn luật: Cal/OSHA Title 8 §5144

Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.

Câu hỏi liên quan cùng chủ đề

Cập nhật gần nhất: · quy trình kiểm tra

Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra
Báo lỗi