Cấp nước & Phân phốiCâu 53 / 360
Where must a readily accessible full-open shutoff valve be provided on the building water supply?
a.On the water supply pipe to the building, so the entire supply can be shut off
b.Only at the water heater
c.Nowhere; a curb stop at the street is sufficient
d.Only at the farthest fixture
Giải thích
A readily accessible full-open control valve is required on the building supply so the whole building can be isolated for repairs. A valve only at the water heater or only at the farthest fixture does not isolate the building, and relying solely on the street curb stop does not meet the on-premises shutoff requirement.
Trích dẫn luật: 2022 California Plumbing Code (CPC) §606.2Luyện miễn phí toàn bộ 360 câu hỏi — không cần đăng ký.
Câu hỏi liên quan cùng chủ đề
- What does an air gap physically prevent that a mechanical check-based device relies on internal parts to prevent?
- During rough-in you must pressure test the water piping. Which is a typical acceptable test for the water distribution system before concealment?
- PEX tubing is being routed through a framing environment where it could be exposed to sunlight through a skylight for extended periods. What limitation applies?
- To allow individual maintenance, where does good practice and code generally require shutoff (angle stop) valves in a dwelling?
- A two-story home has the main run in the crawlspace and risers to the second floor. To minimize pressure loss to upstairs fixtures during simultaneous use, which strategy is best?
- A dental office has vacuum and treatment equipment connected to the potable supply, presenting a health hazard with possible backpressure. Which premise-isolation assembly is appropriate?
Cập nhật gần nhất: · quy trình kiểm tra
Đội Ngũ Biên Tập PrepPass · Đối chiếu với California CSLB C-36 Plumbing Trade Examination · Quy trình kiểm tra